Hotler/Event systems NorthEast LX Analysis v.5.3

Holter Perfect / Holter LX Analysis is the effect of over 35 years of experience of the American Company North East Monitoring.
The unique algorithm allows for creation of unlimited amount of patterns of abnormalities- beats of the same morphology. It eliminates time consuming edition- so called pagination.
The latest achievements of North East Monitoring Company in the field of Holter tests!
System description:
-
DR200/HE and DR180+ compatible.
-
Possibility to configure different settings for different users.
-
Each abnormality or beat is labelled with a different colour, chosen by the user, which makes the ECG curve more clear.
- Access to the current time recording at any moment, from everywhere by the right mouse button- possibility of manual measurement of any segments, elevations or lowering with the possibility of printing of the part that we are interested in.
- Atrial Fibrillation filter- without the filter, the Atrial Fibrillation would be diagnosed as supraventricular abnormality. So, if we have several or dozens thousands of such cases, we are exposed to laborious edition.
- Sampling frequency: The North East Monitoring Analysing System creates the picture of QRS, taking 720 samples per second from the recorder, that is 1 sample every 1,3 msec.
- Paediatric filter allowing to change the diagnostic algorithm by using one button.
- The speed of Analysis: Full analysis from tape recorders takes up to 180 seconds, from digital recorders – up to 90 seconds.
- The possibility of analysis of all types of stimulation (atrial, ventricular and atrioventricular) for all types of cardiac stimulators.
- The possibility of diagnosing all types of significant errors of stimulators: Sense Failure, Capture Failure, and Inhibition.
- HRV Frequency Analysis may be done on the basis of three methods: Hammig’s, Hennig’s and Traingale’s.
- HRV Frequency Analysis may be done with the interpolation of abnormalities or artefacts or without the interpolation (optional).
- Possibility of presenting HRV trends in the 3-D image. Dependence of frequency from power of spectrum and time.
- Frequency analysis may be done on the basis of optionally chosen part of ECG curve of optionally chosen length.
- Possibility to monitor the recording of 12 leads ECG in the real time.
- Full QT analysis from 3 and 12 leads.
- Analysis of QT dispersion.
- Analysis of PR segment.
- Analysis of QRS segment.
- Analysis of ECG curve done simultaneously with the measurement of oxymetry.
- Analysis of ST from 12 channels.
- ST trends in 3-D image from 12 channels. Relations - time, value, and channel. The possibility of full integrity with Internet or hospital network.
- 32 bites program.
- OxyHolter option: possibility to capture ECG and SpO2 simultaneously
(separate oxymetry patient cable required)
- Obstructive apnea syndrome analysis resulting with Apnea Hypopnea Index (AHI).
For event viewing you need to use additional software Event LX
_ NorthEast Monitoring Inc. _ |
|
|
|